Before buying wireless chargers for an office or hotel deployment, request time-averaged power measurements at the wall for the complete proposed system. Separate the adapter on its own, the connected charger with no devices present, and a real device left on the charger after it reports a full battery. Ask suppliers to report each condition separately instead of quoting one unexplained “standby” figure.
For equipment left plugged in between uses, wireless charger standby power belongs in the purchase specification alongside the accessory bundle. The checks below are proposed purchase requirements, not OJD test results or universal consumption limits.

Define the measurement boundary before comparing watts
Start by drawing what sits downstream of the meter. For a deployment energy estimate, measure at the AC input of the power supply feeding the installation. A USB-side measurement excludes the adapter’s own losses and cannot replace a wall-input result.
Write down the charger model and revision, adapter model, cable type and length, and any shared controller or supply. If one adapter feeds several charging positions, record the whole arrangement. Dividing its input by the number of positions gives an allocated figure; it does not show what an independently powered charger would consume.

Keep three conditions separate
- For the adapter alone, connect the specified adapter to mains power with no charger attached. This establishes its no-load input under the recorded conditions.
- For the empty charger, connect the complete kit with every charging position empty. This gives you the baseline for a powered desk or room between users.
- For a device left in place, record the complete kit with the specified device remaining after its display reports a full battery. Label this as an occupied, post-charge observation.
A phone showing 100% can still use energy and request power. Its software, settings and background activity can affect the result. Do not label this measurement standardized empty-charger standby. Record the device model, software, case, battery indication and observation conditions with the result.
Compare the states your installation will actually use
An office charger might sit empty all weekend. A hotel bedside charger may remain occupied for hours after a guest’s phone reports a full battery. Start with the expected use pattern, then choose the states worth measuring. A multi-device station may need empty, partly occupied and post-charge observations for the intended device combinations.
Keep active charging outside the empty-state comparison. Use the 3-in-1 charging-station specification guide to address simultaneous charging separately. A station that performs well under load still needs its idle input documented.

Include the normal indicator setting and any supported sleep or lighting option in the record. An unlit LED does not prove zero power consumption. Our bedside LED indicator guide explains why light behavior needs its own specification. If a setting changes both lighting and charging, identify that change rather than treating the two results as equivalent.
Measure after the relevant transition
Ask how the charger enters the state being measured: initial power connection, device removal, or completion of charging with the device still present. Record the settling period and observation window. A brief reading immediately after unplugging a phone may capture a transition rather than the state expected during a long vacant period.
For cycling or fluctuating behavior, request a time-averaged result and enough supporting data to explain it. A photograph of the lowest meter reading cannot establish the average. Have the laboratory or responsible test engineer choose a suitable measurement method and duration.
Request a report that supports a fair comparison
The official summary of IEC 62301:2026 describes measurement and reporting of power consumption in non-active modes. It does not set maximum consumption requirements or safety requirements. A reference to this standard therefore needs a stated test scope; it is not a universal pass mark for a charger.
Ask the responsible laboratory to confirm the applicable method and edition for your product and market. If a supplier cites a regulation or certification as evidence, request the exact requirement and covered configuration. Keep the measurement method separate from any legal limit or certification claim.
Request these fields in each supplier’s report:
- Sample identifiers, hardware and firmware revisions where available, and the complete adapter-and-cable configuration.
- Measurement location, supply voltage and frequency, ambient conditions, and the state of every charging position.
- How each state was entered, settling time, observation duration and averaging method.
- Meter or analyzer identification, calibration status, and measurement uncertainty suitable for the reported low-power range.
- Average input power for each state, supporting records, sample count and any exclusions or deviations.
If two results differ by an amount comparable to the reported uncertainty, do not rank the products confidently from those numbers alone. Request clarification or a matched repeat measurement. Retain the original results with the reason for the retest.
Turn measurements into a purchasing decision
Agree the acceptance requirement before sample approval. Set it for a defined state and complete configuration, with a stated method and treatment of measurement uncertainty. Review the applicable market requirements and deployment budget before choosing a wattage threshold.
For planning, energy in kWh equals average input power in watts multiplied by hours in that state and divided by 1,000. Multiply again by the number of equivalent installations. Keep shared-supply systems counted as systems, and avoid counting the same hours twice across different states.
For illustration only, a measured difference of 0.2 W over 6,000 empty hours across 500 independent kits would equal 600 kWh. These are hypothetical inputs, not OJD test results or a savings forecast. Actual cost depends on operating hours, occupancy and the relevant electricity tariff. An empty-state calculation also excludes active charging.
Compare the low-power results only after the products meet the deployment’s charging and installation requirements. Check that a lower reported input has not come from an omitted adapter, a different accessory bundle or an operating setting the deployment cannot use. Retain the approved sample and require review of adapter, electronics or firmware substitutions that could affect the result.
Put the test request in the RFQ

For an OJD OEM/ODM wireless charger enquiry, send the model or preferred format, target market, quantity, intended devices and required adapter-and-cable bundle. Describe whether the units will stay powered continuously and which empty or occupied states matter to the installation.
Attach the requested report fields and any proposed acceptance requirement. Ask which evidence already exists for the exact configuration, what additional sample work is needed, and how that work will be quoted. Email frank@szojd.com with the brief. Resolve the test scope and open results before approving the production configuration.
Frequently asked questions
1. What should wireless charger standby power include for a bulk purchase?
For deployment planning, request wall-input power for the complete adapter, cable and charger with no devices present. Identify the configuration and measurement conditions. Keep adapter-only and occupied-device results separate so the quoted figure has a clear meaning.
2. Is an adapter’s no-load rating enough?
No. It describes the adapter without the charger attached. Request a second measurement with the intended cable and empty charger connected, because that is the system left powered between users.
3. Does a phone showing 100% create a standby test?
Not by itself. The phone can still consume energy and request power. Treat it as a separate occupied, post-charge observation, with the phone, software, settings and measurement period recorded.
4. Does an LED switching off mean the charger uses no electricity?
No. The light may switch off while other circuitry remains powered or charging continues. Use an appropriate power measurement and the exact model’s instructions; indicator appearance alone cannot establish consumption.
5. Can a USB meter replace a wall-input measurement?
It can help examine the DC side, but it excludes the power adapter’s own losses. Use the AC-input boundary when comparing the complete kit’s electricity use, and state the measurement location in the report.
6. Does IEC 62301:2026 prescribe a maximum standby wattage?
No. Its official summary covers measurement and reporting for non-active modes, not maximum consumption or safety requirements. Ask a qualified laboratory which method and any separate market-specific limits apply to the proposed product.
7. How should buyers compare a shared adapter with separate adapters?
Measure each complete installation under matched occupancy conditions. State the number of charging positions supplied. Any per-position allocation should retain the whole-system result and should not be presented as a standalone charger measurement.
8. What changes should trigger a review of approved standby results?
Review changes to the adapter, cable configuration, charging electronics, firmware or operating settings that could affect input power. Ask the responsible engineer which measurements need repeating, then update the approved configuration and evidence before accepting the substitution.